Essential details
Size:L(160)*W(90)*H(160) cm
N.W:700 kg
Product Introduction
A test skid with one debulky water hydrocyclone unit installed of two DW hydrocyclone liners and two deoiling hydrocyclone units of each installed of a single liner MF type. The three hydrocyclone units are designed in series to be used for testing the practical well stream with high water content at specific field conditions. With that test debulky water and deoilding hydrocyclone skid, it would be able to foresee the real result of water removal and produced water quality, if the hydrocyclone liners to be used for the exact field and operational conditions.
Technical Parameters
Production Capacities & Properties | Min. | Normal. | Max. | |
Gross liquid Stream(cu m/hr) | 1.4 | 2.4 | 2.4 | |
Inlet Oil content (%) ,max | 2 | 15 | 50 | |
Oil density (kg/m³) | 800 | 820 | 850 | |
Dynamic viscosity of oil (Pa.s) | - | Nor. | - | |
Water density (kg/m³) | - | 1040 | - | |
Fluids temperature (°C) | 23 | 30 | 85 |
Inlet/Outlet Conditions | Min. | Normal. | Max. | |
Operating pressure (kPag) | 600 | 1000 | 1500 | |
Operating temperature (oC) | 23 | 30 | 85 | |
Pressure drop of oil side (kPag) | <250 | |||
Water outlet pressure (kPag) | <150 | |||
Produced oil specification (%) | To remove 50% or above water | |||
Produced water specification (ppm) | <40 |
Nozzle Schedule
Well Stream Inlet | 2” | 300# ANSI/FIG.1502 | RFWN |
Water Outlet | 2” | 150# ANSI/FIG.1502 | RFWN |
Oil Outlet | 2” | 150# ANSI/FIG.1502 | RFWN |
Instrumentation
Two rotary Flowmeters are installed at the water and oil outlets;
Six differential pressure gauges are equipped for inlet-oil outlet and inlet -water outlet of each hydrocyclone unit.
Six differential pressure gauges are equipped for inlet-oil outlet and inlet -water outlet of each hydrocyclone unit.